Test method:
T Heat Source = 70 5°C
DA = 50 mm in contact with heat pipe
DB = 30 mm in contact with heat pipee
Tambient = 25 3°C
Find Q-max while T ≦ 5°C (T = T1-T2)
Final Forming Thickness
|
Q-max Table ( Watt)
|
||||
ø3 mm
|
ø4 mm
|
ø5 mm
|
ø6 mm
|
ø8 mm
|
|
Min. / AVG
|
Min. / AVG
|
Min. / AVG
|
Min. / AVG
|
Min. / AVG
|
|
Flatten T = 2.0mm
|
9 W /11 W
|
12 W/15 W
|
15 W/19 W
|
21 W/27 W
|
/
|
Flatten T = 2.5mm
|
11 W/13 W
|
14 W/18 W
|
18 W/24 W
|
32 W/38 W
|
45W/53 W
|
Flatten T = 3.0mm
|
11 W/13 W
|
15 W/19 W
|
23 W/28 W
|
36 W/42 W
|
51W/60 W
|
Round Pipe
|
11 W/13 W
|
16 W/20 W
|
30 W/35 W
|
40 W/46 W
|
61W/71 W
|